ERL Garfilm
ERL is a film with controlled shrinkage in the transverse direction.
Recommended for thermal lamination application.
Sr.No
Property
Unit
Test Method
Typical Values
General
1
Thickness
Micron
GPL Method
10
11
12
2
Yield
M2/Kg
GPL Method
71.4
64.9
59.5
3
Density
gm/cc
ASTM-D-1505
1.4
1.4
1.4
Mechanical
1
Tensile Strength at break ( MD /TD )
Kg/cm2
ASTM-D-882
1900
1900
1900
2
Elongation ( MD /TD )
%
ASTM-D-882
100
90
90
3
Slip(COF)
--
ASTM-D-1894
0.5
0.5
0.5
Optical
1
Haze
%
ASTM-D-1003
3.5
3.5
3.5
2
Total Luminous Transmission
%
ASTM-D-1003
86
86
86
Thermal
1
Shrinkage @ 150 ° C 30min
ASTM-D-1204
MD
%
2
2
2
TD
%
1
1
1
2
Melting point
° C
DSC
255
255
255
Roll
1
Width -Max
mm
GPL Method
1800
1800
2400
2
Standard Length - Min
Mtrs
GPL Method
6000
6000
6000
3
3a
3b
3c
Standard Length - Max for
Width upto 1600 mm
Width between 1600-2000 mm
Width between 2000-2400 mm
Mtrs
GPL Method
36000
36000
36000
Mtrs
GPL Method
24000
24000
24000
Mtrs
GPL Method
18000
18000
18000
MD
- Machine Direction
TD - Transverse Direction
The foregoing data have been obtained using standard test procedures
on defined specimens. The results should therefore only be regarded
as a general guide to material properties and not as design data.